Unit 2 — Construction and Materials

TM-TOOL-010 — Open Handout TM Chapter: Chapter 3 ELOs: Identify required components and materials; understand component selection criteria Estimated time: 20 minutes


Step 1: Read the TM

Open TM-TOOL-010. Read Chapter 3 — Equipment and Materials completely.

Then come back here.


Chapter 3 Content

Component HF Section VHF/UHF Section
Coupler cores 2× BN-43-202 PCB microstrip (FR4)
Secondary winding 20 turns #28 AWG each Coupled line, 0.1mm gap
Termination resistors 51Ω 1% metal film 51Ω 0402 SMD
Detector diodes 1N5711 (×4) BAT42 SMD (×4)
Filter caps 10 nF, 10µF 100 pF NP0, 10 nF
Meter driver LM324 op-amp Same
Panel meter 100µA FSD (×2) CYD digital (optional)
Range switch 6-position rotary Shared with HF section
Section switch DPDT toggle HF/VHF Same
Connectors SO-239 female (×2) or N N-type (×2)

Component Selection

Review the equipment and materials list in Chapter 3 carefully.

Before building, verify every item on the materials list. Key considerations: - Use the specified component types — substitutions may affect performance or frequency coverage - Non-inductive components are required in RF circuits; standard wirewound resistors are unsuitable - Toroids and ferrite cores are frequency-specific; use the specified core material (#43, #61, #67, etc.) - Connector types affect impedance — match the specified connector to avoid SWR errors

The quality of your materials sets the ceiling on the tool's performance.


Self-Check Questions

SC2-1. List the three most critical components or materials specified in Chapter 3. Why are they critical?

SC2-2. Does Chapter 3 specify non-inductive resistors? If so, where are they used and why does it matter?

SC2-3. What connector type(s) does Chapter 3 specify, and what is the frequency/power justification?

SC2-4. Does Chapter 3 specify a particular ferrite core material or type? What is its significance?

SC2-5. What would be the consequence of substituting a standard wirewound resistor for a non-inductive type in an RF application?


Answer Key

SC2-1. See Chapter 3. Identify items with specific part numbers, special materials, or critical tolerances — these are the ones that most affect performance.

SC2-2. See Chapter 3. Non-inductive types are used wherever standard inductive wirewound resistors would add series inductance that degrades high-frequency performance.

SC2-3. See Chapter 3. SO-239, N-type, BNC, and SMA each have different frequency and power ratings.

SC2-4. See Chapter 3. Ferrite #43 is for 1–100 MHz; #61 for 10–200 MHz; #67 for 50–500 MHz. Wrong material = wrong permeability = wrong coupling.

SC2-5. A wirewound resistor has several microhenries of series inductance. At HF and VHF, this adds inductive reactance proportional to frequency, destroying the resistor's value as a termination or load.


Checkpoint

Before proceeding: - [ ] You have read Chapter 3 completely - [ ] You can name the critical components from memory - [ ] You understand why non-inductive and correct ferrite materials are required

→ Proceed to Unit 3